back to PCB
back to main relays
back to Products
Ideal for motor switching in appliances and HVAC
20A switching capability
Designed for high inrush compressor loads
Semi-sealed construction
Sealed version available
Contact Form
1A
Contact Material
Silver Alloy
Load
Resistive load(COSФ1)
Contact Ratings
Motor: inrush 80A 250VAC
Break:20A 250VAC
Resistive:20A 250VAC
Minimum load
500mA 5VDC
Max Switching Voltage
250VAC
Max Switching Current
20A
Max Switching Power
5000VA
Contact Resistance
100mΩMax at 6VDC 1A
Life Expectancy
Electrical
Mechanical
100,000
Operations (at 30 Operations/minute)
10,000,000
Operations (at 300 Operations/minute)
Insulation Resistance
100MΩMin at 500VDC
Dielectric Strength Between Open Contacts
1000 VAC (50/60Hz for one minute)
Between Contacts and coil
4500 VAC (50/60Hz for one minute)
Operate Time
20ms
Release Time
10ms
Temperature Range
-25°Cto+55°C
Shock Resistance
Operating
_
Extremes
Damage Limits
20G 11ms
100G 6ms
Vibration Resistance
10-55Hz, 1.5mm
Max. switching frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr
Humidity
40-85%
Weight
Approx 23g
Safety Standard
UL, cUL, CQC, TüV
Coil Power 0.9W
Nominal
Voltage
_
(VDC)
Coil Resistance
at20±10%(Ω)
Rated
_
current
mA
Max
_
Operate Voltage
VDC
Min Release
Voltage VDC
Max Applicable
Voltage VDC
At
_
70°C
At
_
23°C
5
28
179.8
3.75
0.5
6.5
8.5
6
40
150
4.5
0.6
7.8
10.2
12
160
75
9
1.2
15.6
20.4
24
640
37.5
18
2.4
31.2
40.8
48
2560±15%
18.75
36
4.8
62.4
81.6
TüV:
MODEL
COILING RATING
CONTACT RATING
TRAF
3 to 24VDC
20A 250VAC
UL:
MODEL
COILING RATING
CONTACT RATING
TRAF
3 to 48VDC
20A 250VAC
CQC:
MODEL
COILING RATING
CONTACT RATING
TRAF
3 to 48VDC
5A 250VAC
cUL:
MODEL
COILING RATING
CONTACT RATING
TRAF
3 to 24VDC
20A 250VAC
Copyrights 2003 CIA - Circuits Interconnection Assembies Ltd -
credits
back
top