2 form A contact arrangements
Immersion cleanable, sealed version available
Meet 3,000V dielectric voltage between coil and contacts
Meet 5,000V surge voltage between coil and contacts(1.2/50ms)
Contact Form
2A
Contact Material
Silver Alloy
Load
Resistive load(COSФ1)
Contact Ratings
5A 250VAC/30VDC
TV-3 (3A@120VAC)
Minimum load
100mA 5VDC
Max Switching Voltage
250VAC/30VDC
Max Switching Current
7A
Max Switching Power
1250VA/150W
Contact Resistance
100mΩMax at 6VDC 1A
Life Expectancy
Electrical
Mechanical
100,000
Operations (at 30 Operations/minute)
10,000,000
Operations (at 300 Operations/minute)
Insulation Resistance
100MΩMin at 500VDC
Dielectric Strength Between Open Contacts
1000 VAC (50/60Hz for one minute)
Between Contacts and coil
4000 VAC (50/60Hz for one minute)
Operate Time
20ms
Release Time
10ms
Temperature Range
-40°Cto+70°C
Shock Resistance
Operating
_
Extremes
Damage Limits
10G 11ms
100G 6ms
Vibration Resistance
10-55Hz, 1.5mm
Max. switching frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr
Humidity
20-85%
Weight
Approx 13g
Safety Standard
UL, cUL, CQC, TüV
Coil Power 0.25W
Nominal
Voltage
_
(VDC)
Coil Resistance
at20±10%(Ω)
Rated
_
current
mA
Max
_
Operate Voltage
VDC
Min Release
Voltage VDC
Max Applicable
Voltage VDC
At
_
70°C
At
_
23°C
3
36
83.3
2.25
0.3
3.9
5.1
5
100
50
3.75
0.5
6.5
8.5
6
144
41.7
4.5
0.6
7.8
10.2
9
324
27.8
6.75
0.9
11.7
15.3
12
576
20.8
9
1.2
15.6
20.4
24
2304
10.4
18
2.4
31.2
40.8
48
9216±15%
5.2
36
4.8
62.4
81.6
Coil Power 0.54W
Nominal
Voltage
_
(VDC)
Coil Resistance
at20±10%(Ω)
Rated
_
current
mA
Max
_
Operate Voltage
VDC
Min Release
Voltage VDC
Max Applicable
Voltage VDC
At
_
70°C
At
_
23°C
3
17
179.6
2.25
0.3
3.9
5.1
5
46
107.9
3.75
0.5
6.5
8.5
6
67
89.9
4.5
0.6
7.8
10.2
9
150
60
6.75
0.9
11.7
15.3
12
267
44.9
9
1.2
15.6
20.4
24
1067
22.5
18
2.4
31.2
40.8
48
4260±15%
11.2
36
4.8
62.4
81.6
TüV:
MODEL
COILING RATING
CONTACT RATING
TRA5
3 to 48VDC
5A 250VAC
5A 30VDC
UL:
MODEL
COILING RATING
CONTACT RATING
TRA5
3 to 48VDC
5A 250VAC /30VDC
TV-3: 3A 120VAC
CQC:
MODEL
COILING RATING
CONTACT RATING
TRA5
3 to 48VDC
5A 250VAC
cUL:
MODEL
COILING RATING
CONTACT RATING
TRA5
3 to 48VDC
5A 250VAC/30VDC
TV-3: 3A 120VAC
Copyrights 2003 CIA - Circuits Interconnection Assembies Ltd -