back to automative
back to main relays
back to Products

 

30A 16VDC switching rating
40A inrush at 16VDC
Smallest power relay
1 Form A and 1 Form C arrangements in single and dual relay packages
For Automotive Applications
Contact Form 1A/AC
Contact Material AgSn
Load Resistive load(COSФ1)
Contact Ratings
 LOAD  FROM A  FROM C(NC/NO)
Max Continuous
Max Break
Max Make
30A
30A
100A
30A
30A
100A
25A
25A
15A
Overload_Current_ 50A 5sec   /   87.5A 0.5sec   /   150A 0.1sec
Minimum load 0.5A 5 sec
Max Switching Power  35~320W
Contact Resistance 100mΩMax at 6VDC 1A
Life Expectancy
Electrical
Mechanical
100,000 at20A Operations (at 60 Operations/minute)
10,000,000 Operations (at 300 Operations/minute)
Insulation Resistance 100MΩMin at 500VDC
Between Contacts and coil 750VAC(50/60Hz for one minute)
Operate Time 3ms
Release Time 1.5ms
Temperature Range
Storage
Operating
-40°C to+155°C 
-40°C to+105°C 
Shock Resistance 6msec up to 30g (No change in the switching state>10μ sec)
Vibration Resistance 10-500Hz, 6g (No change in the switching state>10μ sec)
Max. switching frequency Mechanical:72,000 operations/hr
Electrical:360 operations/hr
Humidity 20-50%
Weight Approx 4g
Voltage 12VDC
Resistance See coil Datd table
Nominal Power 0.55W at 23°C coil temp.and rated coil voltage
Thermal Resistance 50°C per actual coil watt in still air with no contact load current
Nominal
Voltage_(VDC)
Coil Resistance
at20±10%(Ω)
Rated_current
mA
Max_Operate Voltage
VDC
Min Release
Voltage VDC
Max Applicable
Voltage VDC
At_105°C At_23°C
12 254 47.2 6.9 1.2
16.5 27.2
 
Copyrights  2003 CIA - Circuits Interconnection Assembies Ltd - credits